Manifold Termojet in thermal insulation 5+1 up MHS52U125(200)
Manifold with hydraulic separator KGS52V.125(200) — Termojet "2 in 1" unit for multi-circuit boiler rooms: distribution manifold with 5+1 circuits with top outlets , combined with hydraulic separator …
per unit · payment on delivery or by invoice
Technical specifications
Description
Manifold with hydraulic separator KGS52V.125(200) — Termojet "2 in 1" unit for multi-circuit boiler rooms: distribution manifold with 5+1 circuits with top outlets, combined with hydraulic separator GS-26 in one housing. It hydraulically separates the boiler circuit and distributes the heat carrier directly to five main consumers — without a separate separator, extra pipes and fittings.
Operating principle: the built-in hydraulic separator creates a low pressure-loss zone between the heat generator circuit and the consumer circuits, so the pumps operate independently and the boiler works in a stable mode. The manifold section distributes the flow to circuits with a centre-to-centre spacing of 125 mm for Termojet pump groups. The built-in air separator vents gases to the air vent (FM ½″), the sludge trap collects dirt which is drained through a valve FM ½″ — the system operates more quietly and for longer.
Applications: large area houses with many circuits — underfloor heating on each floor, radiator branches, DHW boiler, ventilation; systems with solid fuel boilers; multi-circuit connection of a heat pump in one compact unit — see Termojet heat pumps. If there are two or three circuits, KGS22V.125 (2+1, top) or KGS22VN.125 with combined outlets is sufficient.
Advantages of KGS from Termojet:
- five main circuits + hydraulic separator in one housing — maximum functionality in minimum space;
- air and sludge separation — protection of the boiler and pumps from corrosion and wear;
- thermal insulation and wall mounting brackets included;
- Ukrainian manufacture, affordable price, manufacturer's warranty.
Technical specifications: number of outlets — 5+1 (top), maximum power 60 kW at ΔT=10 °C and 95 kW at ΔT=20 °C, maximum flow rate Gmax 6.35 m³/h, boiler connection — 1¼″, heating circuit connections — 1″, centre-to-centre spacing — 125 mm.
Other configurations — in the catalogue of Termojet manifolds with hydraulic separator.
Frequently Asked Questions
How many consumers can be connected to KGS52V?
Five main circuits with 125 mm centre-to-centre spacing for pump groups plus one additional outlet; total capacity — up to 60 kW at ΔT=10 °C.
When to choose KGS instead of separate separator and manifold?
When space in the boiler room is limited and the configuration is standard: one unit is faster to install, costs less and requires fewer pipes and fittings.