Перейти до основного контенту
Home/Catalog/Manifolds with Hydraulic Separator/Manifold Termojet in thermal insulation 2+1 up MHS22U125(200)
SKU 84040222
Manifold Termojet in thermal insulation 2+1 up MHS22U125(200)1/3
Manifolds with Hydraulic SeparatorOwn production

Manifold Termojet in thermal insulation 2+1 up MHS22U125(200)

SKU 84040222In Stock

Manifold with hydraulic separator KGS22V.125(200) — a Termojet "2-in-1" unit: a distribution manifold for 2+1 circuits with top outlets, combined with hydraulic separator GS-26 in a single body. One c…

Number of outlets: 2+1Qmax: ΔT=10°C: 60 kWQmax: ΔT=20°C: 95 kWGmax: 6,35 m³/hBoiler connection: 1 ¼”
Price · incl. VAT
13 244UAH

per unit · payment on delivery or by invoice

1
Ask Consultation
3D model for engineeringКГС22В.125(200).stepSTEP · 21 МБSTEP
02

Technical specifications

SKU84040222
Number of outlets2+1
Qmax: ΔT=10°C60 kW
Qmax: ΔT=20°C95 kW
Gmax6,35 m³/h
Boiler connection1 ¼”
Heating circuit connection1″
03

Description

Manifold with hydraulic separator KGS22V.125(200) — a Termojet "2-in-1" unit: a distribution manifold for 2+1 circuits with top outlets, combined with hydraulic separator GS-26 in a single body. One compact unit simultaneously hydraulically separates the boiler circuit and distributes heat carrier to consumers — saving space in the boiler room and installation time.

The operating principle combines two functions. The built-in hydraulic separator creates a low pressure-loss zone between the primary boiler circuit and the secondary consumer circuits, so the pumps do not affect each other. The manifold section then distributes flow to circuits with a centre-to-centre spacing of 125 mm to suit pump groups. Additionally, the unit cleans the system: the built-in air separator vents gases to an air vent (female thread ½″), and the dirt trap collects sediment, which is drained via a valve female thread ½″.

Application areas: boiler rooms with 2–3 circuits and separate pumps — underfloor heating, radiators, DHW boiler; systems with solid-fuel boilers. This is also the optimal heat pump piping solution: separation and distribution in one unit — see Termojet heat pumps. Pump group NG-46 with thermostatic valve can be installed on the outlets, for example, pump group NG-46 with thermostatic valve for underfloor heating. If separation is required independently from distribution, consider a standalone hydraulic separator GS-26 1¼″.

Advantages of KGS from Termojet:

  • one unit instead of two — saving space, pipes and fittings compared to a separate hydraulic separator and manifold;
  • air and dirt separation — protection of the boiler and pumps from corrosion and wear;
  • thermal insulation and wall-mounting brackets included;
  • Ukrainian manufacture, competitive price, manufacturer's warranty.

Technical specifications: number of outlets — 2+1 (top), maximum output 60 kW at ΔT=10 °C and 95 kW at ΔT=20 °C, maximum flow rate Gmax 6,35 m³/h, boiler connection — 1¼″, heating circuit connection — 1″, centre-to-centre spacing — 125 mm.

Versions with bottom outlets and combined versions — in the Termojet manifold with hydraulic separator catalogue.

Frequently asked questions

How does the KGS differ from a standard manifold?
By the built-in hydraulic separator: the unit not only distributes heat carrier to circuits, but also hydraulically separates the boiler circuit from consumers and cleans the system of air and dirt.

When to choose the KGS and when to choose separate separator and manifold?
The KGS is advantageous when space is limited and the boiler room has a typical configuration. Separate units offer more flexibility when a non-standard layout or higher output is required.

05

Product reviews

No reviews for this product yet. Be the first!

04

Related Products

All products