SKU: 84040028
Price: 13799 UAH
Availability: In stock
Hydraulic separator GS-28 with thermal insulation — Termojet's senior hydraulic separator with 2″ BSP female connection for high-capacity boiler rooms: up to 150 kW at ΔT=10 °C and up to 250 kW at ΔT=20 °C at a maximum flow rate of Gmax 14.3 m³/h. This is the solution for commercial facilities, boiler cascades, and large industrial boiler rooms where smaller-size separators can no longer handle the flow volumes.
How a hydraulic separator works: a low-pressure-drop zone is created between the primary circuit of the boilers (or cascade) and the secondary circuits of the consumers. When the flow rates of the circuits differ, excess heat-transfer fluid circulates through the separator body — pumps do not fight each other, and each circuit receives its design flow rate. The built-in air separator removes microbubbles to the air vent (½″ BSP male connection), the built-in sludge trap collects dirt at the bottom of the body and drains through a ½″ BSP male valve. The ½″ BSP male temperature sensor port allows connection of boiler-room automation or monitoring systems.
Applications: industrial boiler rooms, hotels, shopping centres, apartment buildings, boiler cascades of 150 kW and above, systems with high-capacity solid-fuel boilers. For heat pumps in large facilities, the GS-28 ensures a minimum stable flow through the heat exchanger — see Termojet heat pumps. Flow distribution after the separator is handled through high-capacity Termojet manifolds, for example the K32N.150(300) manifold for 3+1 circuits, bottom outlets. Smaller size — hydraulic separator GS-27 1½″ up to 145 kW.
Advantages of the Termojet GS-28 hydraulic separator:
Technical specifications: maximum flow rate Gmax 14.3 m³/h, capacity 150 kW at ΔT=10 °C and 250 kW at ΔT=20 °C, 2″ BSP female connection, centre-to-centre pipe spacing 300 mm, height 665 mm, width 240 mm, volume 13.30 l. The full model range from 1″ to 2″ is available in the Termojet hydraulic separators catalogue.
Frequently Asked Questions
When is a 2″ hydraulic separator needed instead of 1½″?
When the total system capacity exceeds 145 kW at ΔT=20 °C or the heat-transfer fluid flow rate exceeds 9.25 m³/h — the limiting values of the GS-27. If your boiler or cascade is connected via 2″ pipework, the GS-28 is the right choice.
Does the GS-28 remove air and sludge?
Yes. The built-in air separator vents gases to an automatic air vent (½″ BSP male connection), and the sludge trap collects sediment at the bottom — drained through a ½″ BSP male valve.
| Gmax | 14,3 м³/год |
|---|---|
| Діаметр | 2”ЗР |
| Міжосьова відстань | 300 мм |
| Qmax: △Т=10°С | 150 кВт |
| Qmax: △Т=20°С | 250 кВт |
| Висота | 665 мм |
| Ширина | 240 мм |
| Об’єм | 13,30 л |