Hydraulic separator Termojet in thermal insulation 1" HS-25

Hydraulic separator Termojet in thermal insulation 1" HS-25

SKU: 84040025

Price: 5297 UAH

Availability: In stock

Hydraulic separator GS-25 with thermal insulation — Termojet hydraulic separator with 1″ BSP male connections for heating systems up to 25 kW at ΔT=10 °C (up to 50 kW at ΔT=20 °C). It creates a low pressure-loss zone between the boiler and consumers, so circuit pumps do not interfere with each other and the boiler operates in a stable mode.

Operating principle: the hydraulic separator divides the primary circuit (boiler) and the secondary circuits (consumers). When flow rates in the circuits differ, the excess heat-transfer fluid circulates through the separator body — each pump receives its calculated flow rate. Additionally, the hydraulic separator performs two more functions: a built-in air separator removes micro-bubbles to an automatic air vent (BSP female ½″ connection), and a dirt trap collects sediment in the lower part of the body — it is drained via a BSP female ½″ valve. A socket for a BSP female ½″ temperature sensor is also provided. The result — less noise, air, and corrosion, longer service life of the boiler and pumps.

Typical applications: boiler room of a private house with 2–3 circuits and separate pumps, systems with a solid-fuel boiler, and low-temperature systems with a heat pump where a stable flow through the heat exchanger is critical — see Termojet heat pumps. Paired with a distribution manifold K22V.125 and Termojet pump groups, the hydraulic separator forms a complete boiler-room assembly.

Advantages of the Termojet hydraulic separator:

Technical specifications: maximum flow rate Gmax 2.1 m³/h, capacity 25 kW at ΔT=10 °C and 50 kW at ΔT=20 °C, connection 1″ BSP male, centre-to-centre distance between ports 150 mm, height 370 mm, width 160 mm, volume 1.83 l.

For more powerful systems, see the larger models in the Termojet hydraulic separators catalogue.

Frequently asked questions

Why is a hydraulic separator needed in a heating system?
It eliminates mutual interference between the boiler pump and consumer pumps: each circuit receives its calculated flow rate, the boiler operates stably and lasts longer.

Does the GS-25 remove air and dirt?
Yes. Built into the body are an air separator with an outlet for an automatic air vent BSP female ½″ and a dirt trap with a drain valve BSP female ½″.

Specifications

Gmax2,1 м³/год
Діаметр1”ЗР
Міжосьова відстань150 мм
Qmax: △Т=10°С25 кВт
Qmax: △Т=20°С50 кВт
Висота370 мм
Ширина160 мм
Об’єм1,83 л