manifold Termojet with flow meters for 10 outlets, stainless steel

manifold Termojet with flow meters for 10 outlets, stainless steel

SKU: 84040TJ-W-10

Price: 12676 UAH

Availability: In stock

Termojet TJ-W manifold with 10 outlets — the central distribution unit of an underfloor heating system for large houses and commercial premises. Body made of stainless steel AISI 304, wall thickness 1.6 mm, profile DN40. Each of the 10 circuits is equipped with a flow meter 0–5 l/min for individual balancing. Main connection — G 1", circuits — G 3/4" Eurocone, spacing 50 mm. Unit length — 580 mm.

Technical Specifications

ParameterValue
Number of outlets10
Main connectionG 1" (female)
Circuit connectionsG 3/4" Eurocone, spacing 50 mm
Manifold length580 mm
ProfileDN40, stainless steel AISI 304
Wall thickness1.6 mm
Flow meters0–5 l/min per circuit
Max. pressure10 bar
Max. temperature110°C
Kit contentsValves with thermometers, air vents, drain valves, check valves

Operating Principle and Balancing of 10 Circuits

In a large house, underfloor heating loops vary in length: a 15 m² room requires a shorter circuit than a 40 m² living room. Without balancing, the shorter loops capture a larger share of the flow — some rooms overheat while others remain underheated. The TJ-W-10 flow meter on each of the 10 outlets allows setting a precise flow rate in each loop in the range 0–5 l/min. The installer reads the transparent rotameter and turns the regulating valve until all rooms reach the design flow rate. The return manifold with M30×1.5 sockets accepts thermal actuators for zone control via room thermostats.

Where It Is Used

Advantages

Underfloor Heating and Heat Pump

A heat pump delivers maximum COP at a heat carrier temperature of 35–40°C. Ten underfloor heating circuits are the ideal load: a large heat-transfer surface at a low temperature, steady pump operation. The stainless steel AISI 304 of the TJ-W-10 manifold withstands operation with glycol heat carriers frequently used in heat pump systems. For more details — visit the Termojet heat pump website.

Frequently Asked Questions

Is a pump-mixing unit required for a 10-outlet manifold?
When operating from a boiler with a temperature above 55°C — yes, it is mandatory. The mixing unit for the manifold blends in cooled return water and reduces the supply temperature to 35–45°C. With a heat pump in low-temperature mode, the unit is needed for hydraulic separation of circuits.

Which manifold cabinet is suitable for 10 outlets?
Manifold cabinet No. 03 is designed for 8–10 outlets. For comparison — the manifold with valves for 10 outlets without flow meters costs less and is suitable for systems without balancing. Full range — in the Termojet underfloor heating system catalogue.

Specifications

Кількість виходів10
Підключення1" - ¾"
Довжина580 мм (L = n×50+80)
МатеріалНержавіюча сталь AISI 304
Макс. температура110°C
Макс. тиск10 бар
Витратомір0–5 л/хв
Підключення виходів3/4" Eurocone, крок 50 мм
ПрофільDN40 нерж. сталь AISI 304
Товщина стінки1,6 мм