Home/Catalog/Underfloor Heating System/Underfloor Heating Manifold/manifold Termojet with flow meters for 11 outlets, stainless steel
SKU 84040TJ-W-11
manifold Termojet with flow meters for 11 outlets, stainless steel1/2
Underfloor Heating ManifoldOwn production

manifold Termojet with flow meters for 11 outlets, stainless steel

SKU 84040TJ-W-11In Stock

The Termojet TJ-W manifold with 11 outlets is designed for large underfloor heating systems: large private houses, townhouses, or commercial premises with numerous zones. Made of stainless steel AISI …

Number of outlets: 11Connection: 1" - ¾"Length: 630 mm (L = n×50+80)Material: Stainless steel AISI 304Max. temperature: 110°C
Price · incl. VAT
13 372UAH

per unit · payment on delivery or by invoice

1
Ask Consultation
3D model for engineering84040TJ-W-11.stepSTEP · 19 МБSTEP
02

Technical specifications

Number of outlets11
Connection1" - ¾"
Length630 mm (L = n×50+80)
MaterialStainless steel AISI 304
Max. temperature110°C
Max. pressure10 bar
Flow meter0–5 l/min
Outlet connection3/4" Eurocone, pitch 50 mm
ProfileDN40 stainless steel AISI 304
Wall thickness1,6 mm
03

Description

The Termojet TJ-W manifold with 11 outlets is designed for large underfloor heating systems: large private houses, townhouses, or commercial premises with numerous zones. Made of stainless steel AISI 304, wall thickness 1.6 mm, manifold length — 630 mm. Each of the 11 outlets has a flow meter 0–5 l/min, allowing individual balancing of each circuit regardless of its length. All 11 sockets of the return manifold comply with the M30×1.5 standard for thermostatic actuators.

Technical Specifications

Operating Principle and Balancing

In large systems with 11 circuits, the difference in loop length can reach hundreds of metres: the shortest circuit (e.g., a 5 m² bathroom) and the longest (a 30 m² living room) have fundamentally different hydraulic resistance. Without balancing, the short loop "consumes" all the flow and the floor in the living room remains cold. Flow meters 0–5 l/min on each supply outlet allow setting the required flow rate on each circuit according to the rotameter reading — the system is balanced within an hour of commissioning. The M30×1.5 sockets accept standard thermostatic actuators, so each of the 11 zones can be controlled by a separate thermostat.

Application Scenarios

  • Large private house. 11 circuits cover a house of 180–250 m² with separate zoning by rooms, corridors, and bathrooms.
  • Boiler + pump mixing unit. Together with the mixing unit for the manifold, the manifold distributes the heat carrier already in the safe range of 35–45°C — none of the 11 loops receives harmful hot water directly from the boiler.
  • Heat pump and low-temperature system. The 11-outlet manifold is the heart of a large low-temperature system that allows the heat pump to maintain a consistently high COP throughout the entire heating season.
  • Zone control of 11 rooms. M30×1.5 actuators + room thermostats = independent temperature in each zone. At night — lower in bedrooms, during the day — in the study or children's room.

Advantages

  • Stainless steel AISI 304 — a reliable alternative to brass manifolds in systems with aggressive or soft heat carriers.
  • Flow meters 0–5 l/min on each of the 11 outlets — prevent system "stagnation" due to unbalanced circuits.
  • M30×1.5 — the mass-market standard for thermostatic actuators, available from any heating supplier.
  • Eurocone G 3/4" — direct connection of PE-RT 16×2 pipe via the Eurocone TJ-EC-162 fitting.
  • Pressure 10 bar / 110°C — the manifold is suitable even for non-standard configurations with elevated heat carrier parameters.

Underfloor Heating and Heat Pump

A heat pump is most efficient at a heat carrier temperature of 35–45°C — this is exactly the range in which underfloor heating operates. The 11-outlet manifold allows covering the entire area of a large house with a single low-temperature system without raising the supply temperature and without losing the pump's COP. If you are building or renovating a house with a heat pump — find out more on the Termojet heat pumps website.

Frequently Asked Questions

Which cabinet is suitable for an 11-outlet manifold?
For the Termojet 11-outlet manifold with a length of 630 mm, the manifold cabinet №04 (for 10–12 outlets) is recommended. If installation of a pump mixing unit next to the manifold is planned — check the cabinet depth and overall dimensions of the unit in advance.

How many outlets are needed for a 200 m² house?
Approximately — one circuit per 15–25 m² depending on the laying pitch and room configuration. For 200 m² that is 8–13 circuits. The 11-outlet manifold covers a typical house of 180–220 m² without the need to install two smaller manifolds. If there are more circuits — consider the option of two manifolds.