Перейти до основного контенту
Home/Catalog/Underfloor Heating System/Manifold Cabinet/Flush manifold cabinet Termojet No.02 (6-8 outlets, 565×575×110 mm)
SKU TJ000202
Flush manifold cabinet Termojet No.02 (6-8 outlets, 565×575×110 mm)1/6
Manifold CabinetOwn production

Flush manifold cabinet Termojet No.02 (6-8 outlets, 565×575×110 mm)

SKU TJ000202In Stock

Termojet manifold cabinet No. 02 — recessed (built-in) — protects and conceals the underfloor heating manifold with 6–8 outlets in a wall niche. Dimensions 565×575×110 mm (width × height × depth) are …

Type: Internal (built-in)Number of outlets: 6-8Width: 565 mmHeight: 575 mmDepth: 110 mm
Price · incl. VAT
2 449₴

per unit · payment on delivery or by invoice

1
Ask Consultation
02

Technical specifications

TypeInternal (built-in)
Number of outlets6-8
Width565 mm
Height575 mm
Depth110 mm
03

Description

Termojet manifold cabinet No. 02 — recessed (built-in) — protects and conceals the underfloor heating manifold with 6–8 outlets in a wall niche. Dimensions 565×575×110 mm (width × height × depth) are designed for a standard 6–8-outlet manifold with or without a pump-mixing unit. Galvanised steel, decorative white-painted door — the cabinet does not spoil the interior and requires no additional finishing.

Technical Specifications

Purpose and Installation Principle

The cabinet is installed in a wall niche during construction or renovation — before the final finish is applied. The depth of 110 mm matches the thickness of a load-bearing partition or is sufficient for installation in a brick wall with a recess cut. The cabinet bottom is perforated to route pipes into the screed or wall. After the manifold is installed, the door locks shut — the assembly looks neat and remains accessible for servicing without dismantling the finish.

The height of 575 mm is designed for a standard manifold with air vents and drain valves. If a pump-mixing unit is also housed in the cabinet, check its height in advance. The lower edge of the cabinet is recommended to be no less than 300–400 mm above floor level for convenient access to the fittings and flow meters.

Applications

  • New construction. The cabinet is built into the wall together with the pipe runs from the screed — manifold installation takes place after the walls are erected and before the final finish.
  • Major renovation. A niche is cut in a brick or aerated-concrete wall — the cabinet is installed after plastering and before tiling or wallpapering.
  • 6-outlet manifold. Standard configuration for an apartment or small house — six circuits are sufficient for 3–4 rooms plus bathroom and hallway. The 6-outlet manifold with flow meters or the 7-outlet manifold fit this cabinet size.
  • 7–8-outlet manifold. For a house with 5–6 rooms — the 7-outlet manifold with flow meters or an 8-outlet manifold fit cabinet No. 02 in terms of width.

Advantages of the Termojet No. 02 Cabinet

  • Recessed configuration — the assembly disappears into the wall, takes no space in the room, and does not spoil the interior.
  • Service access — the door opens at any time for reading flow meters, adjustment, or repair.
  • Galvanised steel — resistance to moisture that is inevitable in the area of pipe fittings.
  • Size matched to a specific number of outlets — no trimming or adjustment needed; the cabinet is designed precisely for a 6–8-outlet manifold.
  • Matching pair — the surface-mount version, the external manifold cabinet No. 02 (565×600×125 mm), is available for surface mounting.

Frequently Asked Questions

Which cabinet to choose: recessed or surface-mounted?
The recessed cabinet No. 02 is installed in a wall niche — a recess at least 110 mm deep is required. If the wall is thin or a niche cannot be made, choose the external manifold cabinet No. 02 (565×600×125 mm): it is fixed to the wall surface without a recess but protrudes 125 mm outward.

Will a pump-mixing unit fit in cabinet No. 02 together with the manifold?
It depends on the size of the unit. Cabinet height is 575 mm, depth is 110 mm. Most pump-mixing units are 150–200 mm wide and are placed beside the manifold. We recommend checking the dimensions of the chosen unit — in particular the pump-mixing unit TJ-MU-40A — before installation. For systems with a mixing unit, it is sometimes more convenient to choose a cabinet one size larger.

05

Product reviews

No reviews for this product yet. Be the first!

04

Related Products

All products