Reversible dirt separator Termojet Dn25 (1")
The Termojet DN25 (1") angled magnetic dirt separator is the solution for heating systems where effective heat-carrier purification is required but installation space is limited. The unit combines mag…
per unit · payment on delivery or by invoice
Technical specifications
Description
The Termojet DN25 (1") angled magnetic dirt separator is the solution for heating systems where effective heat-carrier purification is required but installation space is limited. The unit combines magnetite Fe₃O₄ capture by a removable neodymium rod with gravitational settling of particles in an expanded chamber. The 90° angled connection allows installation in locations where a straight design simply will not fit. DN25 is the standard size for residential heat pumps and medium-capacity boilers.
Technical Specifications
How It Works: Dual Separation and Angled Connection
The heat carrier enters through one port, flows into an expanded separation chamber and exits through a port at 90° — hence the name «angled». Inside the chamber, two parallel processes take place. The first is gravitational: the flow velocity drops and heavy particles (sand, rust, mineral deposits) settle into the lower collection chamber. The second is magnetic: the neodymium rod attracts magnetite Fe₃O₄ particles, which are too light and fine for gravitational settling but are reliably held by the magnetic field. To drain the accumulated sediment — open the bottom drain valve; to clean the magnet — remove the rod, wipe off the black deposit, return it to its position. Both operations are performed without stopping the system.
Where and How It Is Used
- Heat pump in a tight boiler room. DN25 is the most common pipe size for residential heat pumps. The angled connection allows installing the magnetic separator directly at the elbow joint of the piping assembly without modifying the pipework. Magnetite protection is critical here: the heat pump plate heat exchanger has narrow channels where sludge accumulates and blocks heat transfer. For more details — at tjheatpump.com.ua.
- Compact boiler room or wall cabinet. Boilers rated 20–35 kW are often installed in minimal space. The angled separator does not require a straight section — it becomes part of the pipe elbow.
- Heating system renovation. If the pipework is already installed and modifications are undesirable — the angled separator integrates into the existing piping without significant changes.
- Return pipe before the boiler. The most contaminated heat carrier is the one returning from the system. The separator on the return line intercepts sludge and magnetite before they enter the boiler.
- Underfloor heating. At the inlet to the underfloor heating distribution manifold — protects the narrow loops from clogging and corrosion.
Advantages
- 90° angled design. Installed in locations where a straight separator does not fit — without dismantling adjacent nodes or modifying pipework.
- Dual separation. Magnetite is captured by the rod; other particles settle by gravity. Comprehensive protection in a single body.
- Maintenance during operation. Draining the sediment and cleaning the magnet are performed without stopping the heating system.
- Standard DN25 for heat pumps. Matches the pipe size of the vast majority of residential heat pumps up to 15–20 kW.
Heat Pump and Magnetite: Double Threat in Tight Spaces
Heat pump owners face two problems simultaneously: the need to install a magnetic separator (without it, the plate heat exchanger gradually clogs with magnetite and fails) and limited space in the boiler room for additional equipment. The DN25 angled magnetic separator solves both problems: it is installed at the elbow joint of the standard heat pump piping assembly and takes up no additional space. For more details on heat exchanger protection and heat pump piping design — at tjheatpump.com.ua.
Related Products
If installation space allows straight connection — refer to the DN25 Dirt Separator (straight connection, same protection). If additional air removal is required — the DN25 Air and Dirt Separator combines both functions in a single body. Full range — in the Termojet separator catalogue.
Frequently Asked Questions
What is the difference between an angled and a straight dirt separator?
The operating principle and cleaning efficiency are identical. The difference is purely constructive: in a straight separator, inlet and outlet are on the same axis (flow goes straight); in an angled one, inlet and outlet are at 90° (the flow changes direction). The angled model is chosen when there is no straight pipe section of sufficient length on the return line, or when the boiler room layout dictates an angled connection.
Is a flow capacity of 2,7 m³/h sufficient for my boiler?
A flow capacity of 2,7 m³/h for DN25 corresponds to typical heat-carrier flow rates in boiler systems up to 30–35 kW at a standard temperature differential of 10°C between supply and return. For higher-capacity systems or lower temperature differentials, consider DN32.
Product reviews
No reviews for this product yet. Be the first!