Перейти до основного контенту
Home/Catalog/Pumps/Circulator pump Termojet AUTO energy-saving APM-F 50/10-280 mm
SKU 30501028
Circulator pump Termojet AUTO energy-saving APM-F 50/10-280 mm1/3
PumpsOwn production

Circulator pump Termojet AUTO energy-saving APM-F 50/10-280 mm

SKU 30501028In Stock

Termojet AUTO APM-F 50/10-280 mm circulating pump — a large flanged circulating pump of the APM-F series with an ECM motor and electrophoretic anti-corrosion housing coating. Flanged connection DN50 ,…

Diameter: DN50 flangePump length: 280 mmQmax: 25 m³/hHmax: 10 mPower consumption: 20-435 W
Price · incl. VAT
57 389UAH

per unit · payment on delivery or by invoice

1
Ask Consultation
Documents for download5 files
Насоси APM-FБрошури · PDF · 2025PDFСертифікат відповідності — циркуляційні насоси APE, APM, XPS, HSBСертифікати та декларації · PDF · 2025PDFДекларація НЕО (низьковольтне обладнання) — циркуляційні насосиСертифікати та декларації · PDF · 2025PDFДекларація ЕМС (електромагнітна сумісність) — циркуляційні насосиСертифікати та декларації · PDF · 2025PDFДодаток до декларацій — перелік моделей циркуляційних насосівСертифікати та декларації · PDF · 2025PDF
3D model for engineering30501228.stepSTEP · 24 МБSTEP
02

Technical specifications

NameAPM-F 50/10
DiameterDN50 flange
Pump length280 mm
Qmax25 m³/h
Hmax10 m
Power consumption20-435 W
I max2.2 A
Size390*250*455mm
Weight22kg
Fluid temperature0°C ~ 110°C
Outdoor temperature0°C ~ 40°C
Maximum system pressure1,0 MPa
Protection classIP44
Voltage230 V ± 10% / 50 Hz
Thermal classF
Pumped liquid requirementsclean, free of solid particles and mineral oils, non-toxic, chemically neutral, with characteristics close to water
Installationmotor shaft must be in horizontal position
03

Description

Termojet AUTO APM-F 50/10-280 mm circulating pump — a large flanged circulating pump of the APM-F series with an ECM motor and electrophoretic anti-corrosion housing coating. Flanged connection DN50, installation length 280 mm, maximum head 10 m, maximum flow rate 25 m³/h. Designed for commercial and industrial heating and cooling systems where small-size threaded pumps are insufficient.

Technical specifications

Operating modes and control

Constant differential pressure — Δp-c. The pump maintains a set pressure difference between the supply and return pipework regardless of flow rate. Standard choice for large radiator and heating systems with thermostatic control.

Proportional differential pressure — Δp-v. When the flow rate decreases, the pump proportionally reduces pressure and electricity consumption. Recommended for systems with variable load: large underfloor systems, combined circuits, facilities with weather-compensated control.

The motor shaft is installed horizontally. The heat carrier must be a clean liquid free of solid particles and mineral oils, chemically neutral, with properties close to water.

Applications

  • Boiler rooms of office and warehouse premises requiring a capacity of up to 25 m³/h at a head of up to 10 m.
  • Heating and cooling systems of medium and large commercial facilities with DN50 flanged connection.
  • Heat carrier circulation in solar energy and hot water supply systems (temperature range 0–110 °C).
  • Replacement of an outdated DN50 flanged pump in a boiler room. For compatible equipment — Termojet Mega series and Termojet pump groups.

Why ECM is more advantageous than an unregulated pump

An unregulated DN50 pump of comparable capacity consumes constant power regardless of load. The APM-F 50/10 consumes 20–435 W depending on the current load: when the flow rate decreases, consumption is significantly reduced. The energy efficiency index EEI < 0,21 confirms the energy-saving equipment class.

Wet rotor technology and water-cooled motor: no shaft seals, no wearing parts — the pump requires no maintenance. The electrophoretic housing coating protects against corrosion in long-term operation.

  • EEI < 0,21 — confirmed energy efficiency class.
  • Wet rotor + water cooling — no maintenance required.
  • IP44 — splash protection, suitable for boiler rooms.
  • Ukrainian manufacture: no customs delays, fast delivery, official warranty.

For systems with a heat pump

For large commercial facilities with a heat pump, the APM-F 50/10 provides the required capacity of 25 m³/h with an energy-efficient ECM motor. The temperature range 0–110 °C covers all heat pump operating modes. More about heat pumps for commercial facilities — Termojet heat pumps.

Frequently asked questions

Does the APM-F 50/10 require a three-phase supply?
No. The APM-F 50/10 pump is powered by a single-phase supply 230 V ± 10% / 50 Hz. Three-phase power is not required — this simplifies installation in boiler rooms without three-phase wiring.

What are the heat carrier quality requirements?
The heat carrier must be a clean liquid free of solid particles and mineral oils, non-toxic and chemically neutral. For selecting larger DN65 models — see the Termojet Mega series.

05

Product reviews

No reviews for this product yet. Be the first!

04

Related Products

All products