Home/Catalog/Pumps/Energy-saving recirculation pump Termojet SPE12/1.4S with timer and thermostat
SKU 4535487
Energy-saving recirculation pump Termojet SPE12/1.4S with timer and thermostat1/2
PumpsOwn production

Energy-saving recirculation pump Termojet SPE12/1.4S with timer and thermostat

SKU 4535487In Stock

Termojet SPE12/1.4S recirculation pump — a low-power pump for domestic hot water (DHW) recirculation systems with built-in timer and thermostat. Threaded connection ½″ BSP , maximum flow rate 0,6 m³/h…

Maximum flow rate: 0,6 m³/hMaximum head: 1,4 mConsumed power: up to 9 WConnection size: 1/2" FTFluid temperature: +2°C~ +110°C
Price · incl. VAT
7 741UAH

per unit · payment on delivery or by invoice

1
Ask Consultation
3D model for engineeringSPE12-1.4S.stepSTEP · 3 МБSTEP
02

Technical specifications

Maximum flow rate0,6 m³/h
Maximum head1,4 m
Consumed powerup to 9 W
Connection size1/2" FT
Fluid temperature+2°C~ +110°C
Maximum ambient temperature+40°C
Maximum operating pressure10 bar
Protection classIP44
Fluid characteristicsclean, free of solid particles and mineral oils, non-toxic, chemically neutral, with characteristics close to water
InstallationMotor shaft must be positioned horizontally
pH level:6.5 – 8.5
Pump housingstainless steel 304
Motorpermanent magnet
Motor housingaluminium alloy
Impellerpolymer material with magnetic filler
Dimensions/weight16*11*11 / 1kg.
03

Description

Termojet SPE12/1.4S recirculation pump — a low-power pump for domestic hot water (DHW) recirculation systems with built-in timer and thermostat. Threaded connection ½″ BSP, maximum flow rate 0,6 m³/h, head 1,4 m, power consumption up to 9 W. Thanks to continuous recirculation in the return circuit, hot water appears at the tap instantly — without waiting and without wasteful draining of cold water into the drain.

Technical Specifications

Operating Modes: Timer and Thermostat

Timer. The pump switches on and off on a schedule — for example, only during morning and evening peak hot water demand hours. At night and during periods when hot water is not needed, the pump is off — electricity consumption is minimal.

Thermostat. The pump automatically switches off when the set temperature in the return line is reached and switches on again when it drops. This prevents overheating of the return circuit and avoids pointless pump operation when the water is already hot.

The combination of timer and thermostat ensures minimum consumption with maximum comfort: the pump does not run when hot water is already in the line or when it is not needed.

Applications

  • Private houses and apartments with a boiler, where there are more than 5–6 metres of pipe between the water heater and the distant tap — without recirculation, 5–15 l of cold water is drained each time.
  • Hotels, guest houses, offices — where instant hot water is a comfort requirement.
  • Systems with long distribution pipework where water has time to cool between uses.
  • New construction and renovation — the pump is installed on the return line from the tap to the boiler.

Why a Permanent-Magnet Motor Is More Efficient

Old recirculation pumps consume 40–80 W continuously. The SPE12/1.4S consumes up to 9 W — a permanent-magnet motor with low standby consumption. When operating with a timer (for example, 8 hours per day), the actual daily consumption is less than 72 Wh — less than the cost of one cup of coffee.

The housing of stainless steel 304 is corrosion-resistant and suitable for long-term operation in DHW systems. The motor is protected (IP44) and the bearings require no maintenance.

  • Up to 9 W consumption — incomparably less than old unregulated DHW pumps.
  • Timer + thermostat — the pump runs only when needed.
  • Stainless steel 304 housing — durability in DHW systems.
  • IP44 — splash protection.

For Systems with a Heat Pump

If a heat pump provides both heating and DHW via a storage boiler, the SPE12/1.4S recirculation pump maintains continuous hot water availability in the distribution network. The minimal consumption of up to 9 W does not affect the COP of the heat pump system. Learn more about Termojet heat pumps at tjheatpump.com.ua.

Frequently Asked Questions

Is a check valve required during installation?
Yes. A check valve is installed on the return line from the distant tap to the boiler to prevent backflow. Please clarify the installation diagram with a Termojet manager.

What is the difference between SPE12/1.4 and SPE12/1.4S?
The SPE12/1.4S version includes a built-in timer and thermostat. The basic SPE12/1.4 version operates in continuous mode without automatic shut-off. For most residential applications, the version with timer and thermostat is recommended — it consumes significantly less over a year. View SPE12/1.4 without timer.