Pump group Termojet Boiler without mixer 1" FT in thermal insulation without pump PG-67(200)

Pump group Termojet Boiler without mixer 1" FT in thermal insulation without pump PG-67(200)

SKU: 84130670

Price: 7150 UAH

Availability: In stock

Pump group NG-67.200 — a specialised Termojet unit 1″ female thread for quick and convenient connection of an indirect water heater to boiler room equipment. This is a direct group without a mixer: the water heater intentionally receives coolant at the full boiler temperature so that the heat exchanger heats the water as quickly as possible.

The operating principle is simple and reliable: the circulation pump circulates the coolant through the water heater coil, the high flow capacity Kvs 10.2 m³/h minimises hydraulic resistance and reduces DHW heating time. The valves with thermometers 0–120 °C on the supply and return lines show the circuit operating mode and allow it to be shut off for maintenance, while the built-in check valve eliminates parasitic circulation when the pump is off — the water heater does not cool down through adjacent circuits.

Applications: domestic hot water preparation in private homes, DHW circuit in multi-circuit boiler rooms alongside underfloor heating and radiators. An indirect water heater is the standard DHW solution in heat pump systems too — see Termojet heat pumps. In the boiler room the group works alongside the distribution manifold K22V.125 and heating circuit groups, for example NG-46 with thermostatic valve for underfloor heating. Connection to a manifold with a beam spacing of 300 mm — via the adapter KP 200/300.

Advantages of NG-67.200 from Termojet:

Technical specifications: maximum capacity 20 kW at ΔT=10 °C and 40 kW at ΔT=20 °C, connection to manifold and circuit — 1″, working pressure up to 6 bar, dimensions 349×264 mm, volume 0,32 l. Pump installation length — 130 mm; pump purchased separately — the Termojet APE 25-60 pump (130 mm) is suitable.

Other models — in the Termojet pump groups catalogue.

Frequently Asked Questions

Why is the water heater group without a mixer?
An indirect water heater requires the maximum coolant temperature — the hotter the supply to the coil, the faster the water heats up.

Is the circulation pump included in the package?
No, the pump is purchased separately. Installation length — 130 mm; the energy-saving Termojet APE 25-60 (130 mm) is suitable.

Specifications

Підключення до колектора1″
Підключення до контуру опалення1″
Довжина насоса130 мм
Висота349 мм
Ширина264 мм
Qmax: ΔT=10°C20 кВт
Qmax: ΔT=20°C40 кВт
KVS10,2 м³/год
Робочий тискдо 6 бар
Об’єм0,32 л