SKU: 84610490
Price: 11802 UAH
Availability: In stock
Pump group with thermostatic valve NG-46 in EPP BLACK thermal insulation — a pre-assembled Termojet unit for circuits requiring precise supply temperature maintenance without boiler room automation. The three-way thermostatic valve 25–55 °C blends cooled return water and maintains the set temperature, while the proprietary EPP BLACK jacket minimises heat losses in the boiler room and gives the unit a neat appearance.
The operating principle is based on passive return water blending: as soon as the supply temperature exceeds the set point, the thermostatic mixer adds cooled coolant from the return line. Control without electricity — the valve responds to the coolant temperature mechanically, with no actuators or controllers. Valves with thermometers 0–120 °C on the supply and return allow the mode to be monitored and the circuit to be isolated for maintenance without draining the system. The built-in check valve prevents parasitic circulation between adjacent circuits.
Typical scenarios: underfloor heating (it is critical to keep the temperature below 55 °C), low-temperature radiator heating, systems with solid-fuel and gas boilers. For low-temperature heat pump systems, this group ensures precise circuit temperature maintenance — if you are selecting heat pump equipment, see Termojet heat pumps. The group is mounted on Termojet distribution manifolds with a standard centre-to-centre distance of 125 mm, for example manifold K22VN.125 2+1 up+down.
Advantages of the Termojet pump group:
Technical parameters: maximum capacity 15 kW at ΔT=10 °C and 30 kW at ΔT=20 °C, Kvs 3,5 m³/h, connection to the manifold and heating circuit — 1″ female thread, working pressure up to 6 bar, height 395 mm, width 250 mm, volume 0,34 l. Circulation pump installation length — 180 mm; the pump is not included, we recommend the energy-saving Termojet APE 25-60 circulation pump (180 mm). For connection to a manifold with 1¼″ outlets, use adapter KP125/150.
Other models with thermostatic valve and straight pump groups are available in the Termojet pump group catalogue.
Frequently Asked Questions
How does this group differ from the NG-46 with standard insulation?
The EPP BLACK jacket material provides better thermal insulation properties and increased thermal resistance; the pump installation length is 180 mm instead of 130 mm.
Is boiler room automation required to control the 25–55 °C valve?
No. The thermostatic valve responds to the coolant temperature mechanically — this is an electronics-free solution, suitable for simple boiler rooms with manual or basic control.
| Підключення до колектора | 1″ |
|---|---|
| Підключення до контуру опалення | 1″ |
| Довжина насоса | 180 мм |
| Висота | 395 мм |
| Ширина | 250 мм |
| Qmax: ΔT=10°C | 15 кВт |
| Qmax: ΔT=20°C | 30 кВт |
| KVS | 3,5 м³/год |
| Робочий тиск | до 6 бар |
| Об’єм | 0,34 л |