Перейти до основного контенту
Home/Catalog/Underfloor Heating System/Underfloor Heating Manifold/manifold Termojet with flow meters for 3 outlets, stainless steel
SKU 84040TJ-W-03
manifold Termojet with flow meters for 3 outlets, stainless steel1/2
Underfloor Heating ManifoldOwn production

manifold Termojet with flow meters for 3 outlets, stainless steel

SKU 84040TJ-W-03In Stock

The Termojet TJ-W manifold with 3 outlets is a distribution unit for underfloor heating systems with built-in flow meters 0–5 l/min on each circuit. Made of stainless steel AISI 304 with a wall thickn…

Number of outlets: 3Connection: 1" - ¾"Length: 230 mm (L = n×50+80)Material: Stainless steel AISI 304Max. temperature: 110°C
Price · incl. VAT
4 765UAH

per unit · payment on delivery or by invoice

1
Ask Consultation
3D model for engineering84040TJ-W-03.stepSTEP · 18 МБSTEP
02

Technical specifications

Number of outlets3
Connection1" - ¾"
Length230 mm (L = n×50+80)
MaterialStainless steel AISI 304
Max. temperature110°C
Max. pressure10 bar
Flow meter0–5 l/min
Outlet connection3/4" Eurocone, pitch 50 mm
ProfileDN40 stainless steel AISI 304
Wall thickness1,6 mm
03

Description

The Termojet TJ-W manifold with 3 outlets is a distribution unit for underfloor heating systems with built-in flow meters 0–5 l/min on each circuit. Made of stainless steel AISI 304 with a wall thickness of 1.6 mm, DN40 profile. Main line connection — G 1", circuit connections — G 3/4" Eurocone, 50 mm pitch. Suitable for houses and apartments with 3 underfloor heating zones.

Technical Specifications

Operating Principle and Balancing

The manifold receives the heat carrier from the main line through the G 1" inlet and distributes it evenly across three underfloor heating circuits. The flow meter on each outlet is a rotameter with a transparent cap and a float indicator. By adjusting the flow meter valve, the installer sets the required flow in each loop — from 0 to 5 l/min. A longer loop has greater hydraulic resistance and, without balancing, receives less heat. The flow meters eliminate this imbalance: every room heats up equally, regardless of the pipe circuit length. The air vents at the top purge air when the system is started; the drain valves at the bottom are used for flushing or winterisation.

Applications

  • Apartment or small house with 3 zones. For example: living room + bedroom + bathroom. Three independent circuits allow different temperatures to be set in each room using M30×1.5 thermal actuators.
  • System with a heat pump. The manifold is suitable for low-temperature heat carrier 35–45°C, which is optimal for heat pumps. Stainless steel withstands long-term operation with glycol-based heat carriers.
  • Part of a larger system. With 3 circuits in one wing of a house, the TJ-W-03 manifold is installed alongside a second manifold for the other wing — each zone is controlled independently.

Advantages

  • Stainless steel AISI 304 — resistant to corrosion and glycol heat carriers, does not need replacement for decades.
  • Flow meters on each circuit — precise system balancing without expensive auto-balancing inserts.
  • G 3/4" Eurocone standard — direct connection of PE-RT 16×2 pipe via Eurocone without adapters.
  • M30×1.5 sockets on the return manifold — compatible with standard thermal actuators for zone control.
  • Complete package in the box — valves, air vents, drain, check valves assembled at the factory.

Underfloor Heating and Heat Pump

An air-to-water heat pump achieves a COP efficiency of 4–5 at a heat carrier temperature of 35–40°C. Underfloor heating is the only heating system that operates efficiently in this range: it covers the entire floor area and transfers heat at a low temperature differential. The Termojet TJ-W-03 manifold is designed for this mode: stainless steel, maximum temperature 110°C — a reliable safety margin even in bivalent systems with a boiler. Learn more about Termojet heat pumps.

Frequently Asked Questions

Is a mixing unit required for this manifold?
If the heat source is a gas or solid-fuel boiler with a supply temperature above 55°C, a mixing unit for the manifold is mandatory — it reduces the temperature to a safe 35–45°C. With a heat pump, a unit may be needed for hydraulic separation or if the pump delivers more than 45°C.

Which cabinet is suitable for a 3-outlet manifold?
Manifold cabinet No. 00 is designed for 2–4 outlets and is suitable for this manifold — dimensions 335×575×110 mm. Also available is the 3-outlet version with valves without flow meters — if balancing is not required. The full range is in the Termojet underfloor heating system catalogue.

05

Product reviews

No reviews for this product yet. Be the first!

04

Related Products

All products