Dirt separator Termojet Dn50 (2")
Termojet DN50 magnetic dirt separator is designed for large heating systems and boiler rooms with output from 60 to 120 kW and above. Flow capacity 10.1 m³/h with standard G 2" thread. Brass body…
per unit · payment on delivery or by invoice
Technical specifications
Description
Termojet DN50 magnetic dirt separator is designed for large heating systems and boiler rooms with output from 60 to 120 kW and above. Flow capacity 10.1 m³/h with standard G 2" thread. Brass body withstands 110°C and 10 bar. Built-in neodymium magnetic rod captures magnetite Fe₃O₄ — the ferromagnetic iron deposit that no gravitational separator retains. Installed on the return pipeline before the boiler, indirect heating boiler, pump assembly, or heat exchanger.
Technical Specifications
How It Works
The large DN50 chamber volume ensures a sharp reduction in flow velocity — from the working velocity in the pipe to the minimum in the chamber. Non-magnetic particles: coarse abrasive, sand, scale fragments, oxides — settle to the bottom under gravity. Simultaneously, the neodymium rod at the centre of the chamber captures ferromagnetic magnetite particles circulating in the heat carrier in suspension. The dual action — gravitational and magnetic separation — occurs in parallel and continuously. For servicing: the drain valve at the bottom empties accumulated sludge without stopping the system; the rod is removed, cleaned of black deposit, and reinserted.
Applications
- Boiler room 60–120 kW. DN50 (2") is the typical return pipe diameter in commercial and large residential systems. Protects the boiler heat exchanger from sludge that reduces heat transfer and increases fuel consumption.
- Commercial real estate, industrial premises. Heating systems of large buildings generate significantly more magnetite due to the large volume of steel pipework and radiators — the DN50 magnetic separator handles the increased load.
- High-capacity heat pump. Magnetite in the narrow channels of the plate heat exchanger gradually reduces the efficiency coefficient. DN50 covers heat pumps with an output of 20–40 kW with the corresponding pipework. More information at tjheatpump.com.ua.
- Systems with a buffer tank. The large volume of heat carrier in the buffer tank and associated circuits requires a powerful separator — DN50 provides the necessary flow capacity without pressure drop.
- After major renovation or system flushing. The first weeks after any work in the system are the peak of sludge output. The DN50 separator allows rapid removal, keeping the system in continuous operation.
Advantages
- Dual separation — gravitational and magnetic: one device protects against the full spectrum of contaminants.
- Flow capacity 10.1 m³/h — without excessive pressure losses in large systems.
- Removable neodymium rod — magnetite cleaning without dismantling and draining the heat carrier.
- Drain without shutdown — drain valve at the bottom for prompt removal of accumulated sludge during boiler room operation.
Magnetic Separator and Heat Pump
Large heat pumps are especially vulnerable to magnetite: the wide plate heat exchanger has hundreds of narrow channels that become clogged with black iron sludge from corrosion. A conventional dirt separator does not retain this type of deposit. Only a powerful neodymium rod effectively removes magnetite from the heat carrier. More about protecting heat pump systems at tjheatpump.com.ua.
Related Products
If air removal from the heat carrier is also needed, consider the Air and Dirt Separator DN50 as a two-in-one solution. Full separator range — in the Termojet catalogue.
Frequently Asked Questions
Can the DN50 separator handle industrial systems?
The Termojet DN50 separator with G 2" threaded connection is designed for systems up to ~120 kW with the corresponding pipework. For larger industrial systems with higher flow rates or flanged connections, contact Termojet managers — we will select a solution for your project.
How difficult is it to maintain a magnetic separator in a large boiler room?
The procedure is the same regardless of DN: open the drain valve — drain the sludge (1–2 minutes); remove the rod — wipe off the magnetite — reinsert (30 seconds). The system does not need to be stopped. Recommended interval: once every 6 months in the first year, then once a year.