SKU: 84040TJ-R-W-08
Price: 8837 UAH
Availability: In stock
The Termojet manifold with ball valves for 8 outlets — a reliable and affordable heat distribution unit for underfloor heating systems. Stainless steel AISI 304 with a thickness of 1.6 mm, shut-off valves on each circuit, main line connection G 1", circuit connections — G 3/4" Eurocone, M30×1.5 sockets for thermal actuators. Length 480 mm, maximum pressure 10 bar, maximum temperature 110°C.
| Parameter | Value |
|---|---|
| Number of outlets | 8 |
| Main line connection | G 1" female |
| Circuit connections | G 3/4" Eurocone, 50 mm spacing |
| Actuator sockets | M30×1.5 |
| Length | 480 mm |
| Material | Stainless steel AISI 304 |
| Wall thickness | 1,6 mm |
| Max. pressure | 10 bar |
| Max. temperature | 110°C |
The manifold distributes the heat transfer fluid from the main pipe or pump-mixing unit across eight underfloor circuits. A ball shut-off valve is installed at each outlet of the supply and return headers: turn the handle 90° and the circuit is isolated. This allows individual rooms to be disconnected for maintenance, filling, or pressure testing without stopping the entire system. M30×1.5 sockets are standard seats for thermal actuators: install the actuator and connect a room thermostat, and you will get per-circuit temperature control on top of the basic valve configuration.
A heat pump supplies low-temperature heat transfer fluid — 35–45°C — which is optimal for underfloor heating and allows achieving COP 4–5. The Termojet 8-outlet ball valve manifold provides stable distribution of this heat transfer fluid across the circuits. If the system is connected to a heat pump, also consider the version with flow meters — the 8-outlet manifold with flow meters will allow precise system balancing for maximum heating uniformity. For more information on heat pump solutions — visit the Termojet heat pumps website.
When are ball valves sufficient and when are flow meters needed?
Ball valves are a sufficient solution if the underfloor heating loops in all rooms are approximately the same length. If there is a significant difference (for example, a bathroom loop of 20 m and a living room loop of 90 m on the same manifold) — without flow balancing, the short loop will overheat and the long one will underheat. In that case, choose the 8-outlet manifold with flow meters.
Can M30×1.5 thermal actuators be installed on this manifold?
Yes. M30×1.5 sockets are present at each outlet — installing a thermal actuator takes a minute and requires no tools. Connect a room thermostat or underfloor heating controller, and the system will automatically open and close the circuit according to the room temperature. Also note the mixing unit for the manifold, which will provide the required supply temperature.
| Кількість виходів | 8 |
|---|---|
| Підключення | 1" - ¾" |
| Довжина | 480 мм |
| Матеріал | Нержавіюча сталь AISI 304 |
| Макс. температура | 110°C |
| Макс. тиск | 10 бар |