Перейти до основного контенту
Home/Catalog/Additional Equipment/Titanium active anode Termojet with power supply for enamelled boilers TI 400 G3/4"
SKU 21500168
Titanium active anode Termojet with power supply for enamelled boilers TI 400 G3/4"
Additional EquipmentOwn production

Titanium active anode Termojet with power supply for enamelled boilers TI 400 G3/4"

SKU 21500168In Stock

The TI400 titanium anode is an active MMO anode for protecting enamelled (glass-lined) water heaters against corrosion. Unlike a classic magnesium sacrificial anode, the titanium rod with a catalytic …

Model: TI-400Boiler type: Enamelled (vitreous)Power supply type: PE (for enamelled tanks)Boiler volume: 200–500 lConnection thread: G3/4"
Price · incl. VAT
6 193UAH

per unit · payment on delivery or by invoice

1
Ask Consultation
02

Technical specifications

ModelTI-400
Boiler typeEnamelled (vitreous)
Power supply typePE (for enamelled tanks)
Boiler volume200–500 l
Connection threadG3/4"
Stem materialTitanium with Ir–Ta MMO coating
Service life10+ years
PSU inputAC 110–240 V, 50–60 Hz
PSU outputDC max. 10 V / 0.2 A
Ambient temperature0–70 °C
PSU protection degreeIP20
Packaging dimensions455×75×55 mm
Weight in packaging344 g
Installation wrenchSW 27 mm
03

Description

The TI400 titanium anode is an active MMO anode for protecting enamelled (glass-lined) water heaters against corrosion. Unlike a classic magnesium sacrificial anode, the titanium rod with a catalytic coating of iridium and tantalum oxides (Ir–Ta MMO) does not dissolve in water but instead supplies electrons directly into the tank via the power supply unit. The result is continuous electrochemical protection with no sediment, no odour, and no annual replacement. Connection: G3/4", service life — over 10 years. Power supply unit included — type PE, designed specifically for enamelled tanks.

Technical Specifications

Operating Principle

A sacrificial magnesium anode gradually dissolves, neutralising the corrosive environment, and needs replacing every 2–4 years. If not replaced in time, corrosion attacks the enamel and the steel body of the water heater. The TI400 titanium anode works on a fundamentally different principle: the PE-type power supply passes a weak direct current through the Ir–Ta MMO rod into the water. The electrochemical reaction protects the inner surface of the enamelled tank against corrosion without any dissolution of the anode material. The MMO coating is catalytically stable — the rod retains its properties throughout the service life of the water heater.

Important: the PE power supply is calibrated for the parameters of an enamelled vessel. For stainless-steel water heaters, a different anode version with a PS power supply is used — TI400 titanium anode for stainless-steel water heaters.

Applications

  • Replacement of a worn magnesium anode. If you regularly notice a hydrogen sulphide smell ("rotten egg") or see sediment in the water heater — the anode is no longer protecting. The TI400 fits the same G3/4" port and requires no further maintenance.
  • Enamelled water heater 200–500 l. The optimal range for effective active protection — from small household water heaters to tanks for commercial use.
  • Aggressive water with impurities. Soft or acidic water accelerates enamel corrosion and consumes a magnesium anode within 1–2 years. The TI400 active protection is independent of the chemical composition of the water.
  • Long-term savings. A single TI400 anode replaces dozens of magnesium anodes over the entire service life of the water heater — with no service calls or spare-part costs.

Advantages of Termojet TI400 (for enamelled tanks)

  • Does not dissolve — no sediment, no hydrogen sulphide smell after installation.
  • Service life of over 10 years — install once and forget about the anode forever.
  • PE power supply included — precisely matched current for enamelled tanks, with no risk of over-protection.
  • Installation in the standard G3/4" port with SW 27 spanner — no specialist tools required.
  • Eliminates hydrogen sulphide odour — a side effect of active protection: hydrogen does not form and hydrogen sulphide does not occur.

Frequently Asked Questions

Can the TI400 be installed in place of a magnesium anode without replacing the fitting?
Yes. Both anode types use the standard G3/4" connection. Remove the old magnesium anode with an SW 27 spanner, fit the TI400 with PTFE tape, and connect the PE power supply to a 220 V socket. Installation takes 10–15 minutes without draining the entire volume of the water heater.

Why does an enamelled water heater require specifically the PE power supply and not the PS?
Enamel and stainless steel have different electrochemical potentials and different levels of inherent protection. The PE unit supplies a current calculated for the protective potential of an enamel coating: sufficient for complete protection, without excessive current that could damage the enamel or accelerate hydrogen evolution. The PS unit for stainless-steel tanks has different parameters — they must not be interchanged. If your water heater is stainless steel, see TI400 for stainless-steel water heaters; more accessories are in the accessories catalogue.