Distribution manifold К52Н.150(300) — the maximum configuration of the 150 series from Termojet: 5+1 circuits with bottom outlets , boiler connection 2″ and flow capacity up to 175 kW at ΔT=10 °C and …

Number of outlets: 5+1Qmax: ΔT=10°C: 175 kWQmax: ΔT=20°C: 350 kWGmax: 17,5 m³/hBoiler connection: 2″
Price · incl. VAT
22 714UAH

per unit · payment on delivery or by invoice

1
Ask Consultation
3D model for engineeringК52Н.150(300).stepSTEP · 29 МБSTEP
02

Technical specifications

SKU84040563
Number of outlets5+1
Qmax: ΔT=10°C175 kW
Qmax: ΔT=20°C350 kW
Gmax17,5 m³/h
Boiler connection2″
Heating circuit connection1 ¼”
03

Description

Distribution manifold К52Н.150(300) — the maximum configuration of the 150 series from Termojet: 5+1 circuits with bottom outlets, boiler connection 2″ and flow capacity up to 175 kW at ΔT=10 °C and up to 350 kW at ΔT=20 °C. This is a solution for large boiler rooms where five or more independent circuits are supplied from a powerful heat generator or boiler cascade.

150 series header: supply and return lines in a single body, boiler connection 2″, distribution of the heat carrier to five circuits with 1¼″ outlets and a centre-to-centre distance of 150 mm. Additional outlet G ½″ — for a pressure gauge or sensor. Outlets are directed downward: compact routing with bottom pipe routing or when pump groups need to be positioned below the header.

Fields of application: commercial and industrial facilities with multiple heating zones, large installations with a boiler cascade, systems with multi-temperature circuits — underfloor heating in multiple zones, radiator heating, DHW, ventilation, swimming pool. A hydraulic separator GS-28 2″ must be installed upstream of the manifold. For heating large facilities with a heat pump see Termojet heat pumps.

Advantages of the Termojet manifold:

  • five powerful 1¼″ circuits from a single assembly — optimal piping of a large boiler room;
  • boiler connection 2″ — maximum flow capacity up to 350 kW;
  • bottom outlets and 150 mm centre-to-centre — for powerful pump groups of large size;
  • thermal insulation and brackets included, own production in Ukraine, warranty.

Technical specifications: number of outlets — 5+1, maximum capacity 175 kW at ΔT=10 °C and 350 kW at ΔT=20 °C, maximum flow rate Gmax 17.5 m³/h, boiler connection — 2″, circuit connection — 1¼″, centre-to-centre distance — 150 mm.

Smaller configurations of 2–4 circuits and the 125 mm series — in the Termojet distribution manifolds catalogue.

Frequently asked questions

How many pump groups can be connected to this manifold?
Five large-size groups with 1¼″ connection and 150 mm centre-to-centre. The sixth outlet G ½″ — for auxiliary equipment without a pump group.

Is a hydraulic separator mandatory for five circuits?
Yes, with five independent pump circuits the hydraulic separator GS-28 2″ is required — without it the pumps will interact and the hydraulic balance will be disrupted.