Three-way mixing valve Termojet, DN32, kvs-16 female thread
Termojet DN32 three-way rotary mixing valve — high-flow fitting with female thread Rp 1¼" for medium and high-capacity heating systems. Flow coefficient Kvs 16 m³/h , operating pressure PN 10 bar , te…
per unit · payment on delivery or by invoice
Technical specifications
Description
Termojet DN32 three-way rotary mixing valve — high-flow fitting with female thread Rp 1¼" for medium and high-capacity heating systems. Flow coefficient Kvs 16 m³/h, operating pressure PN 10 bar, temperature range –10…+110°C. Body made of brass CW617N, EPDM seals, leakage less than 0.1%. Designed for actuator mounting for automatic proportional supply temperature control.
Technical Specifications
Operating Principle
Three valve ports: A — hot heat carrier from the boiler, B — cooled return from the circuit, AB — mixed supply to the heating circuit. The actuator rotates the plug in the range 0–90° according to a 3-position or analogue controller signal. Smooth rotation angle change continuously regulates the proportion of hot and return flows — the supply temperature to the circuit is set and maintained automatically. EPDM seals guarantee leakage of less than 0.1% of Kvs even during prolonged operation in the closed position.
Applications
- Boiler rooms with a capacity of 40–80 kW. DN32 Kvs 16 covers typical heat carrier flow rates for commercial and large residential boiler rooms — without hydraulic compression of the system.
- Large-area underfloor heating. Mixing unit for underfloor circuits in buildings with an area of 180–300 m² and more, with separate supply temperature control.
- Multi-circuit systems. One DN32 valve at the main boiler outlet before zone distribution — saves space and simplifies the scheme.
- Weather-compensated control. Paired with the Termojet 411 actuator (0–10V, 24V) and a weather-compensating controller, enables precise heating curve adjustment and significantly reduces gas or electricity consumption.
- Commercial and semi-industrial facilities. Office buildings, small production premises, shopping centres — where DN25 is already insufficient in terms of flow capacity.
Advantages of Termojet DN32
- Kvs 16 — high flow capacity for powerful systems without excessive hydraulic resistance at the valve.
- Brass body CW617N — reliable corrosion resistance and precise geometry for long-lasting operation in critical assemblies.
- Plug torque less than 3 Nm — compatibility with standard 6 Nm actuators with a twofold torque reserve.
- Leakage less than 0.1% — minimal uncontrolled bypass between A and B in the closed position.
- Standard actuator mounting flange — quick connection of 405N and 411 actuators without additional parts.
Compatible Actuators
Termojet DN32 valve plug torque — less than 3 Nm. For DN32, actuators with a travel time of at least 60 s are recommended to avoid water hammer in large systems:
- Termojet 405N electric actuator (3-point, 230V, 60 s) — standard choice for boiler rooms with a 3-position controller output, compatible with all DN sizes.
- Termojet 411 electric actuator (0–10V, 24V) — for weather-compensated automation, smart home systems, and heat pump systems with analogue 0–10V output.
Valve and Heat Pump
In systems where the heat pump is the primary heat source for a large residential or commercial facility, the Termojet DN32 Kvs 16 three-way mixing valve provides the required heat carrier flow without excessive pressure drop. Paired with the 411 actuator (0–10V) and a weather-compensating controller — smooth supply temperature adjustment in line with outdoor temperature, increasing the heat pump COP and reducing electricity bills. More details — on the Termojet heat pumps website.
FAQ
When to choose DN32 instead of DN25?
DN32 Kvs 16 — for systems with a heat carrier flow exceeding 6–7 m³/h or boiler capacity from 40–45 kW. If the hydraulic resistance of the DN25 Kvs 10 valve exceeds 0.5 bar at the design flow rate — switch to DN32. For standard private homes with a capacity of up to 30–35 kW, DN25 is usually sufficient.
Can the DN32 valve be installed without an actuator?
Yes. The valve can be fixed manually in any plug position for a fixed mixing temperature setting. However, for automatic weather-compensated or proportional control, one of the compatible 405N or 411 series actuators is required — the system then maintains the optimal temperature automatically without manual adjustments.
Product reviews
No reviews for this product yet. Be the first!
Related Products