SKU: 84040TJ-W-15
Price: 20447 UAH
Availability: In stock
Termojet manifold with flow meters, 15 outlets — a solution for large residential and commercial underfloor heating systems. Body made of AISI 304 stainless steel, 1.6 mm thick, length 830 mm, fifteen flow meters 0–5 l/min ensure precise balancing of each of the 15 independent circuits. Connection G1" / G3/4" Eurocone and sockets M30×1.5 — ready for zone control without additional fittings.
| Parameter | Value |
|---|---|
| Number of outlets | 15 |
| Main line connection | G 1" internal |
| Circuit connections | G 3/4" Eurocone, 50 mm spacing |
| Actuator sockets | M30×1.5 |
| Length | 830 mm (L = n×50+80) |
| Material | Stainless steel AISI 304 |
| Profile | DN40, wall thickness 1.6 mm |
| Flow meter | 0–5 l/min per circuit |
| Max. pressure | 10 bar |
| Max. temperature | 110°C |
With fifteen circuits, the difference in loop lengths between rooms can reach 3–5 times. Without balancing, the shortest loops will "steal" flow, while the longest ones will remain underheated. The flow meter (rotameter) at each outlet shows the actual flow rate in l/min: the installer or owner can directly see which circuit is receiving too much and which too little. The flow meter's regulating valve throttles flow in short loops until all 15 circuits are balanced. The result is uniform floor temperature in every room with no overheating or cold zones. The M30×1.5 sockets accept standard thermal actuators for zone-by-zone control from room thermostats.
A large facility with 15 floor zones and a heat pump is the most efficient low-temperature heating configuration. The heat pump delivers heat carrier at 35–45°C, which is optimal for underfloor heating and provides a COP of 4–5. The Termojet 15-outlet manifold evenly distributes this heat carrier, while the flow meters prevent any zone from "stealing" flow from its neighbours. More about comprehensive heat pump solutions — on the Termojet heat pumps website.
Why do I need flow meters if there are thermal actuators on each outlet?
Thermal actuators control the switching on and off of the circuit based on room temperature — but they do not balance the hydraulics between circuits. With 15 open circuits, the flow difference between a short and a long loop can be 3–4 times. A flow meter allows you to set the balance once when commissioning the system — after that, the thermal actuators only switch the already-balanced circuits on and off.
Can I split 15 circuits into two smaller manifolds instead of one large one?
Technically yes, but a single 15-outlet manifold is more compact and simpler in terms of installation and hydraulics: one main line connection instead of two, one service assembly. If space is limited, refer to the Termojet underfloor heating system catalogue — it has manifolds from 2 to 15 outlets for any configuration.
| Кількість виходів | 15 |
|---|---|
| Підключення | 1" - ¾" |
| Довжина | 830 мм (L = n×50+80) |
| Матеріал | Нержавіюча сталь AISI 304 |
| Макс. температура | 110°C |
| Макс. тиск | 10 бар |
| Витратомір | 0–5 л/хв |
| Підключення виходів | 3/4" Eurocone, крок 50 мм |
| Профіль | DN40 нерж. сталь AISI 304 |
| Товщина стінки | 1,6 мм |