manifold Termojet with flow meters for 8 outlets, stainless steel

manifold Termojet with flow meters for 8 outlets, stainless steel

SKU: 84040TJ-W-08

Price: 10408 UAH

Availability: In stock

The Termojet 8-outlet flow meter manifold is the central heat carrier distribution unit in an underfloor heating system. Stainless steel AISI 304 with 1.6 mm thickness, built-in flow meters 0–5 l/min on each circuit, standard connections G1" / G3/4" and actuator sockets M30×1.5 make it ready for precise balancing and zone control without modifications.

Technical Specifications

ParameterValue
Number of outlets8
Main line connectionG 1" internal
Circuit connectionsG 3/4" Eurocone, 50 mm pitch
Actuator socketsM30×1.5
Length480 mm (L = n×50+80)
MaterialStainless steel AISI 304
ProfileDN40, wall thickness 1.6 mm
Flow meter0–5 l/min per circuit
Max. pressure10 bar
Max. temperature110°C

Operating Principle and Balancing

The manifold consists of two parallel manifold pipes — supply and return. The heat carrier from the main line enters through the G1" port and is distributed evenly across eight underfloor heating circuits. Without balancing, a longer loop has greater hydraulic resistance and receives less heat carrier than a shorter one — some rooms heat less effectively. The built-in flow meter (rotameter) with a transparent cap and colored float shows the actual flow rate in each circuit in l/min. The flow meter's adjustment valve allows reducing flow in short loops to the level of long ones — balancing minimizes the temperature difference between rooms. The M30×1.5 sockets on each outlet accept standard thermal actuators: with zone control, the thermostat opens/closes a specific circuit without affecting the rest.

Applications

Advantages of the Termojet AISI 304 Manifold

Underfloor Heating and Heat Pump

A heat pump operates most efficiently at a heat carrier temperature of 30–45°C — in this range COP reaches 4–5. Underfloor heating is precisely the system that consumes heat carrier at this temperature. The Termojet 8-outlet flow meter manifold is the heart of the low-temperature circuit: it evenly distributes flow from the heat pump across rooms, and the flow meters prevent any loop from "stealing" flow from others. More about comprehensive solutions — at the Termojet heat pumps website.

Frequently Asked Questions

What is the difference between a flow meter manifold and a valve manifold?
A valve manifold (with shut-off valves) only allows opening or closing an individual circuit. The 8-outlet valve manifold is suitable for simple homogeneous systems where all loops are approximately the same. A flow meter manifold adds precise flow metering — you see l/min in each loop and adjust the balance according to actual hydraulics. For a house with rooms of different sizes and loops of different lengths — flow meters are mandatory.

Which manifold cabinet is suitable for the 8-outlet manifold?
The 84040TJ-W-08 manifold at 480 mm is designed for manifold cabinet No. 02 (6–8 outlets, 565 mm wide). If a pump-mixing unit is installed nearby — account for its dimensions when choosing the cabinet depth.

Specifications

Кількість виходів8
Підключення1" - ¾"
Довжина480 мм (L = n×50+80)
МатеріалНержавіюча сталь AISI 304
Макс. температура110°C
Макс. тиск10 бар
Витратомір0–5 л/хв
Підключення виходів3/4" Eurocone, крок 50 мм
ПрофільDN40 нерж. сталь AISI 304
Товщина стінки1,6 мм